Weitere Informationen
Liste der individuell veränderbaren DICOM Attribute
- Patient Name (0010,0010) – one name for all (all patient names will be concatenated to one), individual name for different names (e.g. Doe-001^John, Doe-002^John, …), individual name for male, female or other (e.g. Doe^John, Doe^Jane, Gollum^Smeagol – last and first names can be chosen individually)
- Patient ID (0010,0020) – individual ID for each patient (automatic modification of Study, Series and SOP Instance UIDs)
- Patient Birthdate (0010,0030) – any date with possibility to leave year or month or day unmodified
- Study Description (0008,1030)
- Series Description (0008,103E)
- Referring Physician’s Name (0008,0090) – individual name in DICOM Format
- Performing Physician’s Name (0008,1050) – individual name in DICOM Format
- Operator’s Name(0008,1070) – individual name in DICOM Format
- Study ID (0020,0010) – individual Index length and start value, e.g. 000001
- Requesting Physician’s Name (0032,1032) – individual name in DICOM Format
- Station Name (0008,1010) - individual name in DICOM Format
- SOP Instance UID (0008,0018) - new UID
- Study Instance UID (0020,000D) - increasing UID
- Series Instance UID (0020,000E) - increasing UID
Liste der löschbaren DICOM Attribute [0008, xxxx]
- Instance Creator UID (0008,0014)
- Institution Code Sequence (0008,0082)
- Referring Physician’s Address (0008,0092)
- Referring Physician’s Telephone Numbers (0008,0094)
- Referring Physician’s Identification Sequence (0008,0096)
- Institutional Department Name (0008,1040)
- Physician(s) of Record (0008,1048)
- Physician(s) of Record Identification Sequence (0008,1049)
- Performing Physician Identification Sequence (0008,1052)
- Names of Physician(s) Reading Study (0008,1060)
- Physician's Reading Study Identification Sequence (0008,1062)
- Operator Identification Sequence (0008,1072)
- Admitting Diagnosis Description (0008,1080)
- Admission Diagnosis Code Sequence (0008,1084)
- Referenced Study Sequence (0008,1110)
- Referenced Performed Procedure Step Sequence (0008,1111)
- Referenced Patient Sequence (0008,1120)
- Referenced Image Sequence (0008,1140)
- Source Image Sequence (0008,2112)
Liste der löschbaren DICOM Attribute [0010, xxxx]
- Issuer of Patient ID Sequence (0010,0021)
- Other Patient IDs (0010,1000)
- Other Patient Names (0010,1001)
- Other Patient IDs Sequence (0010,1002)
- Patient’s Birth Name (0010,1005)
- Patient Age (0010,1010)
- Patient Size (0010,1020)
- Patient Weight (0010,1030)
- Patient's Address (0010,1040)
- Insurance Plan Identification (0010,1050)
- Patient’s Mother Birth Name (0010,1060)
- Additional Patient History (0010,21B0)
- Patient’s Telephone Numbers (0010,2154)
- Ethnic Group (0010,2160)
- Occupation (0010,2180)
- Patient Comments (0010,4000)
Liste der löschbaren DICOM Attribute [0018ff, xxxx]
- Protocol Name (0018,1030)
- Image Comments (0020,4000)
- Requested Procedure Description (0032,1060)
- Requested Procedure Code Sequence (0032,1064)
- Admission ID (0038,0010)
- Issuer of Admission ID (0038,0014)
- Patient’s Institution Residence (0038,0400)
- Scheduled Procedure Step Description (0040,0007)
- Performed Procedure Step ID (0040,0253)
- Performed Procedure Step Description (0040,0254)
- Comments on Performed Procedure Step (0040,0280)
- Intended Recipients of Results Identification Sequence (0040,1011)
- Person Identification Code Sequence (0040,1101)
- Person Address (0040,1102)
- Person Telephone Number (0040,1103)
- Placer Order Number of Imaging Service Request (0040,2016)
- Author Observer Sequence (0040,A078)
- Person Name (0040,A123)
- Content Creator’s Name (0070,0084)
- Content Creator’s Identification Code Sequence (0070,0086)
Implementierung des DICOM Standards, Part 15 Annex E Attribute Confidentiality Profiles
- Es werden nur Attribute betrachtet, die Teil einer Standard DICOM IOD sind
- Datums- und Zeitangaben werden nicht gelöscht
- Informationen zum Aufnahmevorgang werden nicht gelöscht
- Retired Curve Daten und Overlay Daten werden nicht gelöscht
- Information zu Dosis oder Gerätespezifika, z.B. Detektor, Gantry oder Generator werden nicht gelöscht
- Patient Identity Removed (0012,0062) - YES
- De-Identification Method (0012,0063) - Individual Profile
Die Präambel sowie alle privaten Attribute des DICOM Datensatzes werden generell gelöscht da auch hier vertrauliche Patienteninformationen hinterlegt werden können.